• AA Unit1/3.1 36cores Opgw Fiber Optic Cable
  • AA Unit1/3.1 36cores Opgw Fiber Optic Cable
  • AA Unit1/3.1 36cores Opgw Fiber Optic Cable
  • AA Unit1/3.1 36cores Opgw Fiber Optic Cable
  • AA Unit1/3.1 36cores Opgw Fiber Optic Cable
  • AA Unit1/3.1 36cores Opgw Fiber Optic Cable

AA Unit1/3.1 36cores Opgw Fiber Optic Cable

Application: Communication, Optical Fiber Cable
Type: Optical Cable
Material Shape: Round Wire
Allowed Lateral Pressure: 100(N/100mm)
Allowed Tensile Strength: <100N
Core: Multicore
Samples:
US$ 20/Meter 1 Meter(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory, Trading Company
Diamond Member Since 2023

Suppliers with verified business licenses

Rating: 5.0/5
Shanghai, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (10)

Basic Info.

Model NO.
T-FC074
Certification
CE, ISO9001
Brand
Toem OEM
Sheath Material
Ss
Transport Package
Carton
Specification
Customized
Trademark
NA
Origin
China

Product Description

Fiber optic composite overhead ground wire (OPGW) is a type of overhead ground wire containing optical fibers, which has multiple functions such as overhead ground wire and optical communication. It is mainly used for communication lines in 110kV, 220kV, 500kV, 750kV, and new overhead high-voltage transmission systems. It can also be used to replace the existing ground wire of old overhead high-voltage transmission systems, add optical communication lines, conduct short-circuit currents, and provide lightning protection. Special structures can be customized according to user needs.

Product Application
Communication lines in high-voltage transmission systems

Product features
1. The cable diameter is relatively large, and a large number of fiber cores can be designed
2. Stable structure and high reliability
3. The tensile strength and short-circuit current capacity are relatively large, which can achieve the best balance between mechanical and electrical performance
4. The best twisted design can obtain the excess length of secondary optical fibers
5. The number of twisted wire layers can be designed as two or three layers
6. Single wire can be a combination of aluminum clad steel wire and/or aluminum alloy wire and aluminum wire


Characteristic  and Performance
  Attenuation Tape Width Polarization mode dispersion(PMD)
@850nm @1300nm @1310nm @1550nm @850nm @1300nm Single Fiber Link capacity(M=20,Q=0.01%)
G652D -- -- ≤0.35dB/km ≤0.21dB/km -- -- ≤0.20ps/km ≤0.1ps/km
G655 -- -- -- ≤0.22dB/km -- -- ≤0.20ps/km ≤0.1ps/km
50/125μm ≤3.0dB/km ≤1.0dB/km -- -- ≥600MHz.km ≥1200MHz.km -- --
62.5/125μm ≤3.5dB/km ≤1.0dB/km -- -- ≥200MHz.km ≥600MHz.km -- --
 
  Type Material Value
Structure Fiber Optic G652D/G655,etc 2~144 cores
Protective tube Stainless steel pipe 1.5~6mm
Twisted single wire Aluminum clad steel/aluminum alloy/aluminum rod 1.5~6mm
Maximum diameter 30mm
Maximum cross-sectional area 500mm2
Mechanical Performance Meet Standard DL/T832-2016
Maximum tensile force(RTS)(kN) 700
Maximum flattening force(N/100mm) 3000
Maximum short-circuit current capacity(40ºC~200ºC)(kA2s) 2000
Minimum bending radius(dynamic) 20D
Minimum bending radius(static) 15D
Environmental Performance Installation temperature range (ºC) -10~+50
Operating and storage temperature range(ºC) -40~+65
Other fiber cores, fiber types, and strand types can all be designed.

Mechanical and environmental performance testing
NO. Technical Parameter
Model Fiber optic cable structure form Maximum number of optical fibers (core) Aluminum clad steel section
(mm2)
Outer diameter

(mm)
Mass per unit length(kg/km) Rated breaking force(kN) 20 ºC DC resistance
(Q/km)
Allow short-circuit current capacity
(40-200ºCkA2.s)
1 T-FC056 1/2.6/20AS+4/2.5/2
0AS+
11/2.8/20AS,Optical unit
2/2.5
48 ≈90 13.2 ≤641 ≥112 ≤0.98 ≥45
2 T-FC057 1/2.6/40AS+4/2.5/4
0AS+
11/2.8/40AS,Optical unit
2/2.5
48 ≈90 13.2 ≤457 ≥57 ≤0.52 ≥67
3 T-FC058 1/2.6/20AS+5/2.5/2

0AS+
11/2.8/20AS,Optical unit
1/2.5
24 ≈100 13.2 ≤674 ≥118 ≤0.93 ≥50
4 T-FC059 1/2.6/40AS+5/2.5/4
0AS+

11/2.8/40AS,Optical unit
1/2.5
24 ≈10 13.2 ≤479 ≥60 ≤0.49 ≥74
5 T-FC060 1/2.6/20AS+5/2.5/2
0AS+
10/3.2/20AS,Optical unit
1/2.5
24 ≈110 14 ≤760 ≥133 ≤0.83 ≥63
6 T-FC061 1/2.8/20AS+5/2.7/2
0AS+
11/3.05/20AS,Optical unit1/2.6
24 ≈110 14.3 ≤791 ≥140 ≤0.80 ≥68
7 T-FC062 1/2.9/20AS+5/2.8/2
0AS+
12/2.8/AA,Optical unit1/
2.7
24 ≈37
≈74(AA
14.1 ≤473 ≥67 ≤0.40 ≥95
8 T-FC063 1/3.0/20AS+5/2.9/2

0AS+

12/2.9/20AS,Optical unit
1/2.8
36 ≈120 14.6 ≤820 ≥145 ≤0.77 ≥73
9 T-FC064 1/3.0/30AS+5/2.9/3
0AS+
12/2.9/30AS,Optical unit
1/2.8
36 ≈120 14.6 ≤700 ≥95 ≤0.55 ≥98
10 T-FC065 1/3.0/40AS+5/2.9/4
OAS+
12/2.9/40AS,Optical unit
1/2.8
36 ≈120 14.6 ≤582 ≥74 s0.42 ≥110
11 T-FC066 1/3.2/20AS+4/3.0/2
0AS+
12/3.0/20AS,Optical unit
2/2.9
72 ≈120 15.2 ≤832 ≥147 ≤0.76 ≥76
12 T-FC067 1/3.2/30AS+4/3.0/3
0AS+
12/3.0/30AS,Optical unit
2/2.9
72 ≈120 15.2 ≤711 ≥96 ≤0.53 ≥101
13 T-FC068 1/3.2/40AS+4/3.0/4
0AS

12/3.0/40AS,Optical unit
2/2.9
72 =120 15.2 ≤591 ≥74 ≤0.40 ≥114
14 T-FC069 1/3.2/20AS+5/3.0/2
0AS+
12/3.0/20AS,Optical unit

1/2.9
36 ≈130 15.2 ≤879 ≥155 ≤0.72 ≥85
15 T-FC070 1/3.2/30AS+5/3.0/3
0AS+
12/3.0/30AS,Optical unit
1/2.9
36 ≈130 15.2 ≤751 ≥102 ≤0.50 ≥114
16 T-FC071 1/3.2/40AS+5/3.0/4
0AS+
12/3.0/40AS.Optical unit
1/2.9
36 ≈130 15.2 ≤624 ≥79 ≤0.40 ≥137
17 T-FC072 1/3.3/20AS+5/3.2/2
0AS+
12/3.2/20AS,Optical unit
1/3.1
36 ≈140 16.1 ≤995 ≥175 ≤0.65 ≥100
18 T-FC073 1/3.3/30AS+5/3.2/3
0AS+
12/3.2/30AS,Optical unit
1/3.1
36 ≈140 16.1 ≤850 ≥115 ≤0.45 ≥140
19 T-FC074 1/3.3/20AS+5/3.2/2
0AS+
12/3.2/AA,Optical unit1/
3.1
36 ≈49
≈96(AA)
16.1 ≤611 ≥86 ≤0.31 ≥170
20 T-FC075 1/3.4/20AS+5/3.3/2
0AS+

12/3.3/20AS,Optical unit
1/3.2
48 =150 16.6 S1055 ≥182 ≤0.60 ≥123
21 T-FC076 1/3.4/30AS+5/3.3/3
0AS+

12/3.3/30AS,Optical unit
1/3.2
48 =150 16.6 s901 ≥122 ≤0.42 ≥165
22 T-FC077 1/3.4/40AS+5/3.3/4

0AS+
12/3.3/40AS,Optical unit
1/3.2
48 =150 16.6 S747 ≥95 ≤0.33 ≥195
23 T-FC078 1/3.4/20AS+4/3.3/2
0AS+

12/3.3/20AS,Optical unit
2/3.2
72 ≈150 16.6 s998 ≥172 ≤0.64 ≥110
24 T-FC079 1/3.4/30AS+4/3.3/3
0AS+
12/3.3/30AS,Optical unit
2/3.2
72 ≈150 16.6 ≤853 ≥116 ≤0.45 ≥147
25 T-FC080 1/3.6/20AS+5/3.5/2
0AS+

12/3.5/20AS,Optical unit
1/3.4
48 ≈170 17.6 ≤1190 ≥198 ≤0.54 ≥150
26 T-FC081 1/3.8/20AS+4/3.6/2
0AS+

12/3.6/20AS,Optical unit
2/3.5
72 ≈170 18.2 ≤1187 ≥199 ≤0.54 ≥156
27 T-FC082 1/3.8/14AS+5/3.6/1
4AS+
12/3.6/14AS,Optical unit
1/3.5
48 ≈180 18.2 ≤1372 ≥252 ≤0.72 ≥125
28 T-FC083 1/3.8/20AS+5/3.6/2
0AS+

12/3.6/20AS,Optical unit
1/3.5
48 ≈180 18.2 ≤1255 ≥211 ≤0.50 ≥175
29 T-FC084 1/3.8/30AS+5/3.6/3
0AS+
12/3.6/30AS,Optical unit
1/3.5
48 ≈180 18.2 ≤107 ≥147 ≤0.35 ≥234
30 T-FC085 1/3.8/40AS+5/3.6/4
0AS+

12/3.6/40AS,Optical unit
1/3.5
48 ≈180 18.2 ≤888 ≥113 ≤0.28 ≥262
31 T-FC086 1/2.7/20AS+4/2.5/2
0AS+
12/2.5/20AS+13/3
8/20AS
Optical unit1/3.5
48 ≈235 20.3 ≤1594 ≥268 ≤0.38 ≥243,4adw

Item Testing Method Acceptance criteria
Pull GB/T7424.2-E1
Load: Based on changes in fiber optic cable structure
Sample length: not less than 10m;
Link not less than 100m
Duration: 1 minute
40% RTS fiber has no significant strain (0.01%), and the fiber has no significant additional attenuation (0.03dB).
60% RTS fiber strain ≤ 0.25%, fiber additional attenuation ≤ 0.05dB (after tension cancellation, there is no significant residual additional attenuation of the fiber (0.03dB)
Flattening GB/T7424.2-E3
Load: According to the above table,
Test 3 points for a duration of 10 minutes
After the experiment, the additional attenuation of single-mode fiber at 1550nm wavelength should not exceed 0.05dB/fiber, and there should be no mechanical damage to the OPGW.
Seepage water GB/T7424.2-F5
Time: 1 hour
Sample length: 0.5m Water height: 1m
No water seepage
Temperature cycling GB/T7424.2-F1
Sample length: not less than 500m
Temperature range: -40 ºC~+70 ºC
Number of cycles: 2 
Insulation time: not less than 12 hours
After experiment,the additional attenuation of single-mode fiber at 1550nm wavelength should not exceed 0.1dB.

Packaging
Standard disc tools

AA Unit1/3.1 36cores Opgw Fiber Optic Cable
AA Unit1/3.1 36cores Opgw Fiber Optic CableAA Unit1/3.1 36cores Opgw Fiber Optic CableAA Unit1/3.1 36cores Opgw Fiber Optic CableAA Unit1/3.1 36cores Opgw Fiber Optic Cable
What We Have In The Field Of Telecom Optical & Electric Cable :
1>Mature and Efficient Supply Chain System And Rich Industrial Resources
2>Complete Materials Demand Solutions For Cable Manufacturing And Technical Services
3>Overall Solutions And Customized Services In Factory Design, Equipment Configuration, Product Development And Rawmaterial Supply

*Quotation Varies According To Customer's Requirements And Quantity Of Products

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now