• Virgin Recycled Anti Electric Trace Polyethylene PE Granules Sheath Material for ADSS Optical Cable
  • Virgin Recycled Anti Electric Trace Polyethylene PE Granules Sheath Material for ADSS Optical Cable
  • Virgin Recycled Anti Electric Trace Polyethylene PE Granules Sheath Material for ADSS Optical Cable
  • Virgin Recycled Anti Electric Trace Polyethylene PE Granules Sheath Material for ADSS Optical Cable
  • Virgin Recycled Anti Electric Trace Polyethylene PE Granules Sheath Material for ADSS Optical Cable
  • Virgin Recycled Anti Electric Trace Polyethylene PE Granules Sheath Material for ADSS Optical Cable

Virgin Recycled Anti Electric Trace Polyethylene PE Granules Sheath Material for ADSS Optical Cable

CAS No.: 9002-88-4
Formula: (C2h4)N
Material: Polyethylene/PE
Usage: General Plastics, Engineering Plastics, Specialty Plastics, for ADSS Optical Cable
Plastic Properties After Heated: Thermoplastic Plastics
Color: White Black with Color Masterbatch If Needed
Samples:
US$ 50/kg 1 kg(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory, Trading Company
Diamond Member Since 2023

Suppliers with verified business licenses

Rating: 5.0/5
Shanghai, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (10)

Basic Info.

Model NO.
T-PE003
Transport Package
Bag/Pallet
Specification
25kg/bag
Origin
China

Product Description

T-PE003 Series Anti Electric Trace Polyethylene Sheath Material For ADSS Optical Cable
The product meets the requirements of gb/t6553-2014 standard, and the adss cable can meet the requirements of dl/t788-2001 standard for anti electric trace optical cables.
Qx1919: For transmission lines with voltage levels of 220kv and below
Qx-1313: For transmission lines with voltage level of 110kv


ADSS(Above 220KV)
Reference Standard GB/T6553-2014 DL/T788-2001 Typical Physical And Mechanical Properties Are As Follows:
Item   Unit Test Method Typical
Density   g/cm3   GB/T 1033.1 1.1
Melt Flow Rate   g/10min   GB/T 3682-2000 0.37
Tensile Strength   Mpa   GB/T1040.3-2006 22.4
Elongation At Break   %   GB/T 1040.3-2006 764
Low Temperature Impact Embrittlement Temperature (-76 ºC)       GB/T 5470-2008 Pass
Volume Resistivity (20 ºC)   Ω·m   GB/T1410-2006 1.6×1014
Environmental Stress Crack Resistance   Fo/h   GB/T 2951.41-2008 Pass
Dielectric Strength   MV/m   GB/T 1408.1-2006 28
200ºC OIT   min   GB/T 2951.42-2008 55
Dielectric Constant       GB/T 1409-2006 2.52
Dielectric Loss Factor    …   GB/T 1409-2006 0.0006
  *Appearance: Uniform color and no impurities. Evaluation: Qualified, meeting the requirements specified by ROHS.
Note: The above typical values are random sampling data.

ADSS(Above 110KV)
Typical Physical And Mechanical Properties Are As Follows:
Item   Unit Test Method Typical
Density   g/cm3   GB/T1033.1 0.965
Melt Flow Rate   g/10min   GB/T 3682-2000 0.39
Tensile Strength   Mpa   GB/T1040.3-2006 33
Elongation At Break   %   GB/T1040.3-2006 902
Low Temperature Impact Embrittlement Temperature (-76 ºC)   ...   GB/T 5470-2008 Pass
Volume Resistivity (20 ºC)   Ω·m   GB/T1410-2006 1.2×10¹3
Environmental Stress Crack Resistance   Fo/h   GB/T 2951.41-2008 Pass
Dielectric Strength   MV/m   GB/T1408.1-2006 27
200ºC OIT   min   GB/T 2951.42-2008 53
Dielectric Constant   ...   GB/T1409-2006 2.52
Dielectric Loss Factor   ...   GB/T1409-2006 0.0006
  *Appearance: Uniform color and no impurities. Evaluation: Qualified, meeting the requirements specified by ROHS.
Note: The above typical values are random sampling data.
Virgin Recycled Anti Electric Trace Polyethylene PE Granules Sheath Material for ADSS Optical Cable
Packaging Storage And Transport

The material must be supplied packaged in such a way as to be protected during transport, handling and storage. The packaging must be in plastic bags, "bigbag", or cardboard box. The packaging must have adequate strength and be free of impurities that may contaminate the product and be protected against moisture as well.

Virgin Recycled Anti Electric Trace Polyethylene PE Granules Sheath Material for ADSS Optical CableVirgin Recycled Anti Electric Trace Polyethylene PE Granules Sheath Material for ADSS Optical CableVirgin Recycled Anti Electric Trace Polyethylene PE Granules Sheath Material for ADSS Optical CableVirgin Recycled Anti Electric Trace Polyethylene PE Granules Sheath Material for ADSS Optical CableWhat We Have In The Field Of Telecom Optical & Electric Cable :
1>Mature and Efficient Supply Chain System And Rich Industrial Resources
2>Complete Materials Demand Solutions For Cable Manufacturing And Technical Services
3>Overall Solutions And Customized Services In Factory Design, Equipment Configuration, Product Development And Rawmaterial Supply

*Quotation Varies According To Customer's Requirements And Quantity Of Products 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now