• Unshielded Large-Log Twisted-Pair Copper Cable Cat. 6 24AWG
  • Unshielded Large-Log Twisted-Pair Copper Cable Cat. 6 24AWG
  • Unshielded Large-Log Twisted-Pair Copper Cable Cat. 6 24AWG
  • Unshielded Large-Log Twisted-Pair Copper Cable Cat. 6 24AWG
  • Unshielded Large-Log Twisted-Pair Copper Cable Cat. 6 24AWG
  • Unshielded Large-Log Twisted-Pair Copper Cable Cat. 6 24AWG

Unshielded Large-Log Twisted-Pair Copper Cable Cat. 6 24AWG

Application: Local Communication Cable, Coaxial Cable, LAN Cable, Long Distance Symmetric Cable, Copper Cable
Conductor Material: Copper
Cover Material: PVC
Type: Cat 6
Material Shape: Round Wire
Conductor Type: Stranded
Samples:
US$ 1.0/Meter 1 Meter(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory, Trading Company
Diamond Member Since 2023

Suppliers with verified business licenses

Rating: 5.0/5
Shanghai, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 30 days
Full Customization
The supplier provides full customization services
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (10)

Basic Info.

Model NO.
T-CC002
Wire Core Material
Bare Copper Wire
Certification
CE, ISO, RoHS, CCC
Model
UTP-13-6-4p
Brand
OEM
Transport Package
Wooden Case, Carton
Trademark
OEM
Origin
China

Product Description

Indoor cable  lines are a new generation of dual-shielded (S / FTP) network cables, with four wire pairs, 2000 MHz bandwidth and a high transmission rate of 40 Gb / s over a distance of 30 meters. It is particularly suitable for connecting servers, switches, panels, and other devices in a data center. Cat. 8.  1 / 8.  Class 2 network cable is downward compatible with Cat. 7 / 7A and Cat. 6A
The network cable, which can support 25G Base-T at a distance of more than 30 meters (tentative) and 10G Base-T at a distance of 100 meters, can be applied to high speed and bandwidth dense places outside the data center, and can also support Ethernet power supply (Power over Ethernet) applications (POE / POE +).


Features:
Product information Copper guide diameter: 0.53mm cable diameter: 6. 00mm sheath material: PVC / LSZH sheath color: light blue / gray flame retardant performance: GB / T 18380. 12 (IEC 60322-1-2) Operating temperature: -20ºC ~ + 75ºC Packaging mode: 305 m / box application standard GB / T 18233 (ISO / IEC 11801); GB 50311; TIA / EIA568-C. 2, etc


Application standards:
GB / T 18233 (ISO / IEC 11801); GB 50311; TIA / EIA568-C. 2, etc



Specification:
Transmission performance    
Frequency(MHz) 4 31.25 62.5 100 200 250 350
Attenuation IL(DB/100M) 3.2 9.5 13.7 17.5 23.1 27.9 31
Near end crosstalk attenuation(NEXT)(dB) 94.7 63.2 67.3 62.7 63.9 55.8 48.2
The um of proximal crosstalk attenuation power PS NEXT(dB) 78 63.3 67.4 61.2 54.3 52.9 50.9
Equal-level distal crosstalk attenuation(ACR-F)(dB) 77 78.9 84.5 83.8 84.9 70.5 60.9
Equal-level distal crosstalk attenuation power PS (ACR-F)(dB) 72.8 62.8 72.4 70.9 69.7 65.3 60.3
Echo loss PL (dB) 32.8 38.6 32.8 38.6 32.5 27.8 25.3